Amendment status not verified — confirm the current text below against the official source.
Subs. by Act 49 of 2007, S. 3(5), for “includes any person”, w.e.f. 27.5.2008. 3 15[(f) “Steam-pipe” means any pipe through which steam passes, if— (i) the pressure at which steam passes through such pipe exceeds 3.5 kilogram per square centimetres above atmospheric pressure; or (ii) such pipe exceeds 254 millimetres in internal diameter and the pressure of steam exceeds 1 kilogram per square centimetres above the atmospheric pressure, and includes in either case any connected fitting of a steam-pipe;] 16[(g) “Structural alteration, addition or renewal” means,— (i) any change in the design of a boiler or boiler component; (ii) replacement of any part of boiler or boiler component by a part which does not conform to the same specification; or (iii) any addition to any part of a boiler or boiler component; (h) “superheater” means any equipment which is partly or wholly exposed to flue gases for the purpose of raising the temperature of steam beyond the saturation temperature at that pressure and includes a re-heater; (i) “Technical Adviser” means the Technical Adviser appointed under sub-section (1) of section 4A.] 17[2A. Application of Act to feed pipes Every reference in this Act [except where the word “steam-pipe” is used in clause (f) of section 2], to a steam-pipe or steam-pipes shall be deemed to include also a reference to a feed-pipe or feed- pipes, respectively.] 18[2B. Application of Act to economisers Every reference in this Act to a boiler or boilers [except in clause (ccc) of section 2, 19[***] 20[***] shall be deemed to include also a reference to an economiser or economisers, respectively.]